Copper telecommunication ducted cable (FSP-JF-LAP)
Feature
Copper telecommunication ducted cables (FSP-JF-LAP) are used for primary and secondary distribution networks, (i.e., in the secondary network between cross-connection cabinets and the subscribers’ connections, in the primary network between the exchange and cross-connection cabinets) and produced for ducted underground installation with black PE sheath it is suitable for tropical environmental conditions (from -10 °C to +60 °C).
Description
- Up to 200 pairs following REA – PE 89 (USA), TCVN 8238:2009, IEC 60708
- Conductor size: 0.4mm; 0.5mm; 0.65mm; 0.9mm.
- Copper telecommunication ducted cables (FO) type is designed by solid pure annealed copper conductor, high density polyethylene foam skin or solid (skin) insulated, paired, ten or twenty-five pairs sub-unit type, jelly filled, polyester tape wrapped (PS tape), screened with aluminum moisture barrier and black polyethylene sheathed, ducted type, primary and secondary local telephone cable.
Structure

Technical specification
I. Electrical and transmission characteristics
1. Conductor resistance at 200C
2. Insulation resistance at 200C
The insulation resistance shall not be less than 10000 MW/km at 20°C.
3. Dielectric withstand voltage
4. Mutual capacitance
5. Capacitance unbalance at 1000 ± 200 Hz
6. Transmission attenuation
II. Mechanical characteristic